2005/08/28

The introduction of 3Ware 9500S-8 (1)

In 2005/08/13 Server was produced with the AMD Athlon64 x 2 3800+, but SATARAID5-LPPCI of Kurouto Sikou (SiliconImage Sil3114) being embarrassed to the slowness of the transfer rate of RAID5 Card, it decided the introduction of 3Ware 9500S-8.

SATARAID5-LPPCI and if you use, as read-only small-scale File Server I think that also price is good cheaply, but when HDD receives the damage, which HDD there is, only a price fit function such as the fact that specification is difficult.

It is the price which becomes matter of concern, but SATARAID5-LPPCI of professional inclination 3Ware 9500S-8 80,000 Yen or less does also approximately 20 times vis-a-vis 4,000 Yen.

If you mention RAID5, the veteran business manufacturer of the rank, 3Ware (presently affiliation of the AMCC corporation) being to be, as for worry concerning function it is not left over.

Because SATARAID5-LPPCI was 4Ports, 300GB x (4 - 1) = 900GB becomes maximum capacity, but 3Ware 9500S-8 being to be 8Ports 300GB x (8 - 1) = 2100GB increases capacity at once to 2TB.

Furthermore, HDD which is used is SEAGATE ST3300831AS (300GB SATAII 7200), but 8 using, it is not noise or not to almost be, the groan you think that from the fact that, good selection was possible even from the point of quiet sound conversion.

By the way, problem, how doing, was the point whether whether you push in 8 HDD into PC Case, and, it assures the cooling HDD which it adds.

In regard to cooling, it cuts off PC Case, already 1 has decided to add 12cm Fan. Because it means to cut off PC Case, the chip scattering, when Mother Board does Short, because it is troubled, one time PC which was assembled is disassembled completely.


When the cutting of PC Case itself completes, next PC Case Panel is processed.



Lastly, the installation of HDD is done. HDD, it assembles 4 it adds first, installs in the sabot of PC Case. In this case, when you install that way, because air cooling of the basis surface of HDD of the lowest step is not possible, you raise with the spacer.



Next door the which is made to touch being not to be in AGP, Slot it does, 3Ware 9500-8S, but when the serial cable is installed, in order HDD to interfere, I installed inevitably in contiguity Slot.

Actually operating, when I see, it works favorably either the problem of IRQ and the like without.

Furthermore, because the rpm of CPU Fan and HDD Fan publishes the BIOS picture, please refer.


The introduction of 3Ware 9500S-8 it continues in (2)...



Copyright (c) 1999 - 2006 takajun. All rights reserved.